Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CDX5070 | OPTICAL PICKUP RECEIVED FROM NPC DOES NOT WORK IN UNIT | The unit came in for service with type KSS-410A opticalpickup, which was defective. The type shown in the service manual isKSS-313A, which was ordered from NPC and installed in the unit, but thispickup did not work in the customer's unit. Is there a pa | ||
Sony | CDX45 | DISCS DON'T SPIN, "E04" SHOWN ON DISPLAY (REPLACED IC13,Q21) | Loads the CD but will not spin, shows E04 on display. | ||
Sony | CDV701 | MOST FUNCTION BUTTONS DO NOT OPERATE/CHECK EJECT BUTTON | Most of the function switches do not operate. A selected fewwill respond. Unit resembled having a button stuck in the activated mode. I was not able to track this down by checking key scan lines to and fromthe micro. I was able to determine the fault | ||
Sony | CCDTR82 | NO STEADY SHOT | No steady shot indicator showed in viewfinder. | ||
Sony | CCDTR77 | NO CAMERA OUTPUT/RESOLDER L710 | The camera had no output. The problem was caused by L710 onthe VC136 board being poorly soldered on one side. Re-soldering resolvedthe problem.L 710 is in the camera 5v line. When it opens the camera sections isbasically dead. | ||
Sony | CCDTR71 | ONLY ZOOMS ONE WAY/REPLACE IC855 | Unit would only zoom in the direction that zoom was firsttried at power-on. If you tried wide first, it would only zoom wide untilyou turned power off. After killing power if you tried tele first, wouldonly zoom in the telephoto. | ||
Sony | CCDTR71 | BROKEN VIEW FINDER LATCH | View finder latch breaks off and you must replace (or at leastorder) the entire right cabnet to fix it. Can the latch be made aseperate part number? -HQ COMMENTS: We investigated this before, and found it to be tooexpensive to get a sufficient quantity | ||
Sony | CCDTR70 | NEW VC-145 DOES NOT WORK CHANGE PAGE F ADD 00 TO DATA 5E | New VC-145 does not work | ||
Sony | CCDTR7 | LOSES Y SIGNAL AFTER A FEW MINUTES/REPLACE C318 | Would lose Y signal after unit was on for a few minutes. | ||
Sony | CCDTR400 | NOISY CAPSTAN, INTERMITTENT ROTATION/REPLACE CAPSTAN MOTOR | Noisy capstan, intermittent rotation. | ||
Sony | CCDFX620 | PART NUMBER FOR TELE/WIDE SWITCH INCORRECT/1-692-257-21 | Drawing in S/M is incorrect showing plug in flex connector andswitch board. Flex board is actually part of switch assy. | ||
Sony | CCDFX530 | DRUM PROBLEM/RESOLDER IC505 | Drum assy runs extremely fast. | ||
Sony | CCDFX530 | NO FOCUS, NO ZOOM/REPLACE LENS BLOCK | No focus, no zoom | ||
Sony | CCDFX510 | PREMATURE TAPE END DETECTION | We need clarification on CSV-3 Service Bulletin #333. The partlisted as C865 is a filter cap on the focus motor B+ line on p.116. Thedrawing in the S/B shows C559, which is a filter on 5V regulator IC508 onp.122. Which cap should be changed for this symp | ||
Sony | CCDF55 | JAPANESE CHARACTERS FOR MONTH ON OSD, LCD DISPLAY OK | Due to water damage, we had to replace the CT21 board on thisunit. After installation, we could not get the OSD to display the datecorrectly. Either it was yy/mm/dd or mm/dd/yy, but with the month inJapanese characters. |