SonyGDM17SE1SCREEN SLOWLY DISAPPEARS CHECK C625 ON THE G-BOARD The symptom of screen slowly diappearing was caused by C625failure. -HQ COMMENTS: Thank you. Please see Bulletin 70.
SonyCPD15SF1MISCONVERGENGE CAUSED BY A BOARD SHIELD CASE (DEGAUSS CASE)
SonyCPD15SF1INTERMITTENT FOCUS PROBLEM, DEGAUS CRT NECK WITH UNIT ON Focus changes intermittently. -HQ COMMENTS: Degauss the CRT around the neck area while the unit is inthe ON position. This may remove the problem. If this fails to work,replace the picture tube.
SonyCPD15SF1BAD PURITY CAUSED BY RELAY RY601 Bad purity.
SonyWMD3REPLACEMENT OF DRIVING LEVER ASSY CAUSES MECH IRREGULARITIES After replacing X35781420 driving lever assy for splitgears, unit will grind or slip into FF and Rew. -HQ COMMENTS: Please refer to FPR N1126.
SonyTCDD7NO FUNCTIONS (REPLACED LOADING MOTOR M1001 P/N 1-698-104-11) No functions. The unit would not power up.
SonyMDRIF510PART NO FOR HEADBAND WIRE Need part no for headband wire. No part listed in svc man.Please advise if part is avail or not. -HQ COMMENTS: Contact Kansas City Parts, attn Jamie Lyon, phone #816-891-7550 ext 256, fax # 816-891-2580.
SonyD802KAUTO DIMMER WORKS WRONG - INSTALL RESISTOR R904 Backlight on display goes out completely, when sensor iscovered. Discover resistor R904 on main PC board missing (fell off).
SonyD421SPINTERMITTENT AUDIO FROM THE HEADPHONES Headphone jack failed, very loose.
SonyD34UNIT WOULD NOT PLAY - REPLACE CN502 Unit would not play with main board installed. CD wouldspin in reverse or spin without any output. Unit would play fine ifboard was separated from rest of unit. -SOLUTION CN502 was defective. When board was installed and flex calbepositioned it di
SonyD335READS TOC BUT CAN'T READ 1ST 10 SEC ON ESP Customers disc-' All 4 one. Unit would read TOC but 1st 10sec after that on ESP mode had trouble. Had exact copy of same disc.I tried it on and it worked. Problem was with customer disc it had aflaw on the inner track.
SonyD223CD WILL NOT SPIN - REPLACE RACK (REF 58). CD will not spin and optical is loose on screw assy, ref 15,rack is broken.
SonyD133DEFECTIVE DISPLAY, DEFECTIVE FOP AND LEAKY Q409 Unit has defective display ink leaking in display. FOP alsobad. RF reads very low. Battery leakage problem.
SonyD131HOLD SWITCH BROKEN AND BATTERY LEAKS. Unit found with battery leakage also hold switch broken.
SonyD131DEFECTIVE DISPLAY Defective display, broken inside. Caused ink all over thedisplay could not read numbers.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.